2021-06-04 16:36:32 News Center

The operation preparation and procedure of TCM superfine pulverizer are as follows

 

The application of the ultra micro pulverizer is very wide. It has a very big effect on the extraction of effective components and the increase of absorption rate. It is of great practical significance to improve the efficacy and quality of Chinese medicine, reduce the waste and consumption of resources, and improve the social and economic benefits of enterprises.

Preparation for operation of ultra fine pulverizer of traditional Chinese medicine:

Check if there is a "in good" certificate of equipment.

Open the grading assembly and carefully check whether there are metal objects and sundries in the crushing room.

Check the hopper and the auger for foreign material.

It is necessary to check whether the bolts at the connection of each component are tight and reliable.

Carefully check whether the tension of triangle belt and chain is moderate and whether the passport is installed.

Turn the driving parts by hand to see if there is abnormal phenomenon, then click each motor to see if the running direction is correct. a. Rotation direction of grinding disk: looking down counter clockwise;

b. Rotation direction of screw conveyor: left rotation direction;

c. Rotating direction of the grading impeller: opposite to the grinding disk.

The operator shall check the current, temperature and vibration condition for 10-20 minutes without load operation. If there is no abnormality, the normal feeding production can be carried out.

Operation procedure of ultra micro pulverizer of traditional Chinese medicine:

Start up sequence

Start the pulse dust collector to turn off the fan and the indicator light is on;

Start the shakelong fan and the indicator light is on;

Start the high-pressure fan and the indicator light is on;

Start the classifier, and the indicator light is on, adjust the required speed of the classifier and confirm the normal operation clockwise;

Start the main motor, and the indicator light is on, and confirm that the main motor operates counter clockwise and the current is stable;

Start the feeding motor, first open the plug plate to adjust the motor speed of the screw conveyor to the low value. Slowly increase the speed of the spiral conveyor motor according to the current of the main machine, so that the main machine can work under the appropriate load.

 